		Digital Display: 
		Displays the demand limit, current demand, last period 
		average, peak period average, and override status. 
		 
		Real Time Clock/Timers: 
		Allows some or all controlled loads to be scheduled on or off 
		during preselected hours.  If your utility offers a discount on demand 
		during off peak hours, a timer may be used to increase your demand limit 
		during those hours.  In the even of a power outage the correct time and 
		scheduling will be maintained by a high quality battery backup. 
		 
		Permanent 
		Memory:  State-of-the-art 
		EEPROM (electrically erasable programmable memory) is used to preserve 
		critical information in the even of a power interruption.  No batteries 
		required. 
		 
		Adjustments in Tenths Of Kilowatts: 
		Allows you to make changes and receive information to the 
		tenth of a kilowatt for settings up to ten KW.  (Settings over 10 KW can 
		be adjusted in half kilowatt increments). 
		 
		Circuit Override: 
		Allows you to temporarily change the priority of one or more 
		loads for a period of 6 minutes to 99 hours.  This may prove quite 
		helpful if you need to use an appliance which is currently shed.  You 
		may also choose to disable a load during this cycle. 
		 
		Programmable ON/OFF Times: 
		Adjustable on and off times, from on to 15 minutes, add 
		flexibility and efficiency.  Minimum on and off times are factory set at 
		six minutes for compressor protection, but may be adjusted to fit 
		individual applications.   
		 
		Choice of Automatic or Manual: 
		You may choose to have your demand limit adjusted 
		automatically by the computer for seasonal changes, between a maximum 
		and minimum you select, or manually adjust it yourself at will. 
		 
		Data Lock: 
		Protects stored data from being inadvertently changed. 
		   | 
		  | 
		
		 
		Flexible Priority Strategies: 
		You may assign up to 8 levels of priority to each control 
		point.  Unlimited combinations of fixed and/or rotating load priority 
		groups are selectable to fit the needs of every household. 
		 
		Individual Control Points: 
		Eight control points are available.  Individual control 
		points offer the greatest flexibility and 
		convenience.  Up to 16 loads may be controlled with the use of optional 
		relays (2 loads per control point).   
		 
		Programmable Demand Averaging Period: 
		Averaging periods may be adjusted to 15, 30, or 60 minutes to 
		match your particular utility company.  This will allow for the greatest 
		efficiency in control strategies. 
		 
		Choice of Enclosed or Open Frame Relays: 
		The SYSTEM 1000 comes standard with high performance 
		industrial quality enclosed or open frame relays. 
		 
		Variety of Relay Enclosures: 
		Options include flush mount, surface mount, hinged, and/or 
		lockable.  Enclosure sizes range from 8 by 10 by 4 to 12 by 24 by 4. 
		 
		Individual Testing: 
		Each unit is carefully tested and "burned-in" for reliability 
		and performance. 
		 
		Compatible with all Heating and Cooling 
		Systems:  Whether you have 
		heat pumps, air conditioners, electric furnaces, baseboard heating, 
		electric boilers, or radiant heat; the SYSTEM 1000 will give you the 
		highest possible performance. 
		 
		2-5 Years Limited Warranty: 
		The SYSTEM 1000 comes with a standard two year warranty.  An 
		additional three years of warranty is available at a minimal charge. 
		 
		UL Listed: 
		The SYSTEM 1000 meets or exceeds Underwriters Laboratory Inc. 
		requirements. 
		   | 
		  | 
		 | 
		  | 
	
	
		|   | 
		 | 
		
		 
		
		TECHNICAL  
		SPECIFICATIONS  
		
		CONTROL MODULE: 
		Mounting:  In Relay Enclosure. 
		Connections:  Card Edge & Terminal Strips. 
		Power Requirements:  Class II, 12 VAC, 4 watts, 60Hz. 
		 
		TYPICAL RELAY ENCLOSURES: 
		Dimensions:  10"w x 12"h x 4.0"d  (Other sizes available). 
		Enclosure type:  NEMA 3R Rain tight, screw cover. 
		Operating Temperature:  -40F to +170F . 
		Power Requirements:  120 VAC, 60Hz.   40 watts maximum, 4 watts standby. 
		Relays:  Electromechanical.  Two 3 amp pilot-duty SPDT and up to eight 
		30 amp  1 1/2 HP SPDT  (DPDT optional ). 
		 
		CURRENT TRANSFORMERS: 
		Two ring type with 48" 600 volt leads. 
		Standard type:  200: 1 amp Class 2  200 amp rating. 
		Dimensions:  2.4" OD x 1.1" ID x 0.8" width. 
		(400 and 600 amp ratings also available). 
		
		(Specifications subject to change without 
		notice.)  | 
		  |